soil sensors

Radio transmitters & repeaters

soil sensors icon

RF aerocom

RF data modem for PC and repeter with Aerocom radio Tranmission range up to 5 KM line of sight
soil sensors icon

RF Xbee

RF data modem for PC and repeater with XBee® Radio Modems

XBee Radio Specifications:
Radio Module: Digi , XBee-PRO® 802.15.4

Performance:
Outdoor RF line-of-sight Range Up to 1 mile (1600m).
Transmit Power Output 60mW (18dBm).
RF Data Rate 250,000 bps.
Serial Interface Data Rate 9600 bps.

General:
Operating Frequency ISM 2.4 GHz.
Operating Temperature 40 to 85°C (industrial).
soil sensors

cellular

soil sensors icon

cellular

Wireless (Cellular) communication utilizes GPRS technology to enable limitless distance issues and to ensure low cost reliable communication between all system elements. Users enjoy high performance and worldwide global availability. Phytech offers cellular solutions for transmitters and repeaters.
soil sensors

Logging

soil sensors icon

Logging sensors communications

POWER SUPPLY
Operate using one or two 3.6 V lithium batteries. Operation time is about 12 months at 30-minute sampling rate.

DATA LOGGER
Can store up to 420 recor
ds. Each record includes an instant measured value with the appropriate time stamp.

Sampling time is selectable from 10 min to 4 hours. Resolution is 10 to 12 bit depending on the sensor’s type. A special communication transducer and PC program are required for communicating between a logging sensor and a PC.

GENERAL SPECIFICATIONS
Battery life: 12 months
Interface: RS232 via a special communication transducer.
Data exchange rate: 9600
Sampling rate: 10 to 240 min
Memory capacity: 420 records
Resolution: 10 to12 bit.
Accessories: A communication transducer and a program for PC
 
soil sensors

Industrial

soil sensors icon

Industrial sensors communications

The Industrial series of the phytomonitoring sensors were designed for the use with the most of commercial data loggers.

Each sensor has 0-2 Vdc, and optional 4-20 mA or 0-20 mA output, selectable by the user. Fit for use with most of commercial data loggers and data acquisition systems.

 

 